PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a(R134a):
for HFO-1234yf(R1234yf):
REMOVE NO. 1 ENGINE UNDER COVER ASSEMBLY
REMOVE REAR ENGINE UNDER COVER RH
REMOVE REAR ENGINE UNDER COVER LH
REMOVE FAN AND GENERATOR V BELT
REMOVE FRONT SUSPENSION MEMBER REINFORCEMENT LH
REMOVE FRONT SUSPENSION MEMBER REINFORCEMENT RH
REMOVE FRONT SUSPENSION CROSSMEMBER SUB-ASSEMBLY
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the discharge hose sub-assembly.
Remove the O-ring from the discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR ASSEMBLY WITH PULLEY
Disconnect the 2 connectors.
Detach the clamps and disconnect the wire harness.
Remove the 2 bolts and 2 nuts.
Detach the clamp.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor assembly with pulley.