ЭЛЕКТРОВАКУУМНЫЙ КЛАПАН (для EVAP) СНЯТИЕ


  1. REMOVE V-BANK COVER


    1. Remove the 2 nuts and cover.

  2. REMOVE VACUUM SWITCHING VALVE ASSEMBLY (for EVAP)

    A01DVAX

    1. Disconnect the connector.

    2. Disconnect the 2 hoses.

    3. Remove the bolt and switching valve.