PROCEDURE
INSPECT COOLER (NO. 2 ROOM TEMP. SENSOR) THERMISTOR
| *a | Component without harness connected (Cooler (No. 2 Room Temp. Sensor) Thermistor)) |
| *b | Resistance (kΩ) |
| *c | temperature (°C (°F)) |
| *d | Allowable Range |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temp. must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (see the graph).
If the result is not as specified, replace the cooler (No. 2 room temp. sensor) thermistor.