GENERATOR(for 100 A Type) REMOVAL
PROCEDURE
PRECAUTION
Note:After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereClick hereClick hereClick hereClick hereClick here
REMOVE FAN AND GENERATOR V BELT
REMOVE WIRE HARNESS CLAMP BRACKET
Detach the wire harness clamp from the clamp bracket.
Remove the bolt and clamp bracket.
REMOVE GENERATOR ASSEMBLY
-
Disconnect the generator connector.
Remove the terminal cap.
Remove the nut and disconnect the generator wire.
Remove the bolt and wire harness clamp bracket.
-
Remove the 2 bolts and generator assembly.
-