STOP AND START SYSTEM(for 3ZR-FAE) Stop and Start System does not Operate (Battery Condition)
| DTC Code | DTC Name |
|---|---|
| Stop and Start System does not Operate (Battery Condition) |
DESCRIPTION
When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.
Oper Permission (Battery) |
Oper Permission (Start Min Volt 1) |
Oper Permission (Start Min Volt 2) |
Oper Permission (Start Min Volt 3) |
Oper Permission (Start Min Volt 4) |
Oper Permission (Battery Current) |
Oper Permission (Integrated Current) |
Oper Prohibition (Jump Start) |
PROCEDURE
CHECK DTC OUTPUT
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs.
Powertrain > Stop and Start > Trouble Codes
Result
Proceed to
DTCs are not output
DTCs are output
READ VALUE USING GTS
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery condition
NG / OK
OK: Stop and start control is permitted based on battery condition, or Active Test (forced permission) is performed
-
Oper Permission (Start Min Volt 1)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Battery Current)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery discharge current is -125 A or higher
Engine stop and start ECU calculated value
Oper Permission (Integrated Current)
Permission of stop and start control based on the integrated current value condition
NG / OK
OK: Integrated current value more than specified
The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.
Oper Prohibition (Jump Start)
Prohibition of stop and start control based on the jump start condition
Permit / Prohibit
Prohibit: Engine started with the engine hood open and the ignition switch turned START
When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
Oper Permission (Battery Current)
Oper Permission (Integrated Current)
Oper Prohibition (Jump Start)
Result
Proceed to
NEXT
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the battery conditions or other conditions.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Type
Range
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG / OK
OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Proceed to
NG is displayed
OK is displayed
OK is displayed END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)
Tip:Check whether stop and start control was prohibited based on the battery charge control mode.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Status of Battery Charge Control
Battery charge control status
Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode
-
-
Powertrain > Stop and Start > Data List
Tester Display
Status of Battery Charge Control
Result
Result
Proceed to
"Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed
A
"Refresh Charge Mode" is displayed
B
"Abnormal Mode" is displayed
C
"Battery Condition Judgment Mode" is displayed
D
Tip:If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.
B END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE)
D END (STOP AND START CONTROL PROHIBITED IN BATTERY CONDITION JUDGMENT MODE)
READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))
Tip:Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Type
Set battery type
Specified / Other
Specified: Specified battery
Other: Non-specified battery
-
Oper Permission (Start Min Volt 1)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
Result
Proceed to
OK is displayed for 2 or more items
OK is displayed for 1 item or none
The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Temp (Start)
Battery temperature at engine start
Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Same as temperature around battery at engine start (after engine start)
-
Min Voltage(Cranking)
Minimum voltage when cranking engine
Min.: 0 V
Max.: 327.67 V
6 to 11 V
Lowest battery voltage measured in a 5 second period after the starter starts operating.
Min Volt(After Cranking)
Minimum voltage when starter begins operation
Min.: 0 V
Max.: 327.67 V
6 to 11 V
Minimum battery voltage while starter driving
Powertrain > Stop and Start > Data List
Tester Display
Battery Temp (Start)
Min Voltage(Cranking)
Min Volt(After Cranking)
Permission Criteria (Specified Battery)
Tester Display
Starting Battery Voltage
Battery Temperature*
Oper Permission (Start Min Volt 1)
7.65 V or higher
0°C (32°F) or lower
Oper Permission (Start Min Volt 2)
7.65 V or higher
Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3)
7.66 V or higher
0°C (32°F) or lower
Oper Permission (Start Min Volt 4)
7.66 V or higher
Higher than 0°C (32°F)
*: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
Permission Criteria (Non-specified Battery)
Tester Display
Starting Battery Voltage
Battery Temperature*
Oper Permission (Start Min Volt 1)
8.92 V or higher
0°C (32°F) or lower
Oper Permission (Start Min Volt 2)
8.92 V or higher
Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3)
8.92 V or higher
0°C (32°F) or lower
Oper Permission (Start Min Volt 4)
8.92 V or higher
Higher than 0°C (32°F)
*: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
OK is displayed for 1 item or none READ VALUE USING GTS (BATTERY TYPE)Click here
READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))
Tip:Check whether stop and start control was prohibited based on the battery discharge current battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery Current)
Permission of stop and start control based on the battery condition
NG / OK
OK: Battery discharge current is -125 A or higher
Engine stop and start ECU calculated value
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery Current)
Result
Proceed to
OK is displayed
NG is displayed
The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Current
Battery current
Min.: -125 A
Max.: 124.99 A
-
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Current
Permission Criteria
Tester Display
Battery Current
Oper Permission (Battery Current)
-125 A or higher
NG is displayed END (REDUCE ELECTRICAL LOAD)
READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))
Tip:Check whether stop and start control was prohibited based on the integrated current value battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Integrated Current)
Permission of stop and start control based on the integrated current value condition
NG / OK
OK: Integrated current value more than specified
The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the battery temperature.
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Integrated Current)
Result
Proceed to
NG is displayed
OK is displayed
OK is displayed READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)Click here
READ VALUE USING GTS (INTEGRATED CURRENT)
Tip:Judge the battery condition based on the integrated current value.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Integrated Current
Battery integrated current
Min.: -268434.45 A-sec
Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge / discharge conditions)
-
Powertrain > Stop and Start > Data List
Tester Display
Integrated Current
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Fluid Temperature
Battery temperature
Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up
-
Idle
Engine idling status
ON / OFF
ON: Accelerator pedal fully released
OFF: Accelerator pedal depressed
This is sent from the ECM.
Battery Current
Battery current
Min.: -125 A
Max.: 124.99 A
-
-
Ambient Temp Sensor
Ambient temperature
Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient air temperature
-
Integrated Current
Battery integrated current
Min.: -268434.45 A-sec
Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge / discharge conditions)
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Idle
Battery Current
Ambient Temp Sensor
Integrated Current
Standard Integrated Current Value
Status of Battery Charge Control
Battery Fluid Temperature
Integrated Current
Proceed to
Charge Control Coordination Mode or Stop and Start Standalone Mode
-
Below -13478 A-sec
A
Low Temperature Mode
Between 3°C (37.4°F) and 11°C (51.8°F)
Below -6048 A-sec
Low Temperature Mode
Between -1°C (30.2°F) and under 3°C (37.4°F)
Below -3974 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode
-15°C (5°F) or higher or below 75°C (167°F)
Below 0 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode
Below -15°C (5°F) or 75°C (167°F) or higher
-
B
Cause and Action to be Taken
Result
Cause
Action to be Taken
A
Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery
Check the battery condition and recharge or replace the battery
B
Integrated current value is limited for stop and start control due to battery temperature (too high/low)
Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.
Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).
*: Use the GTS to perform Integrated Current Value Initialization.
Tip:If the Data List item "Integrated Current" is 0 or higher, it is not necessary to perform initialization.
When the battery state sensor assembly current value is normal, recharge or replace the battery
Result
Proceed to
NEXT
NEXT END (RECHARGE OR REPLACE BATTERY)
READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)
Tip:Check the operation of the backup boost converter.
Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
State of BBC
Backup boost converter status
Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status
Normal: Backup boost converter operating normally
Cycle Err:
-
Abnormal output voltage cycle is detected
Overvol:
-
When the ignition switch is ON:
-
Overvoltage is detected at the control IC power source within the backup boost converter
Overheating is detected at the control IC power source within the backup boost converter
-
When boosting:
-
Malfunction is detected in the feedback circuit in the backup boost converter
Too high or low output voltage
Overload:
-
Overcurrent is detected.
Low Vol:
-
A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.
Duty Err:
-
Abnormal duty ratio is detected
BBC Check Result
Backup boost converter check result
Normal / Abnormal
-
-
Powertrain > Stop and Start > Data List
Tester Display
State of BBC
BBC Check Result
Result
Proceed to
Normal is displayed
Normal is not displayed
READ VALUE USING GTS (OPER PROHIBITION (JUMP START))
Tip:Check whether stop and start control was prohibited based on the jump start battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Prohibition (Jump Start)
Prohibition of stop and start control based on the jump start condition
Permit / Prohibit
Prohibit: Engine started with the engine hood open and the ignition switch turned START
When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Jump Start)
Result
Proceed to
Permit is displayed
Prohibit is displayed
The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Hood Courtesy Switch
Hood courtesy switch signal
ON / OFF
ON: Engine hood closed
OFF: Engine hood open
-
Oper Permission (Engine Hood Closed)
Permission of stop and start control based on the engine hood open/close condition
NG / OK
OK: Engine hood closed
-
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
Oper Permission (Engine Hood Closed)
Permission Criteria
Tester Display
Conditions
Oper Prohibition (Jump Start)
OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed)
Tip:A jump start is determined if the engine is started with the engine hood open.
Replace if the battery is deteriorated.
A jump start determination is canceled if the engine is started with the engine hood closed after the ignition switch is turned off.
Prohibit is displayed READ VALUE USING GTS (HOOD COURTESY SWITCH)Click here
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the battery temperature battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG / OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Proceed to
NG is displayed
OK is displayed
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Fluid Temperature
Battery temperature
Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up
-
Ambient Temp Sensor
Ambient temperature
Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient temperature
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
Permission Criteria
Tester Display
Battery Temperature*
Oper Permission (Battery)
Current battery temperature is between -10°C (14°F) and 70°C (158°F)
Tip:*: Read the Data List items "Battery Fluid Temperature" and "Ambient Temp Sensor" when checking the battery temperature.
OK is displayed END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (BATTERY FLUID TEMPERATURE)
Tip:Check the battery temperature.
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Fluid Temperature
Battery temperature
Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up
-
Ambient Temp Sensor
Ambient temperature
Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient temperature
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
Result
Proceed to
Proceed to
Both Battery Fluid Temperature and Ambient Temp Sensor are suitable temperature
A
Battery Fluid Temperature or Ambient Temp Sensor is not suitable temperature
B
Tip:If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.
B END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL BATTERY TEMPERATURE)
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the alternator status battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery condition
NG / OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Proceed to
NG is displayed
OK is displayed
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Alternator Status
Generator power generation status
Normal / Abnormal
Normal: Generator operation normal
-
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
Permission Criteria
Tester Display
Conditions
Oper Permission (Battery)
Normal is displayed for Alternator Status (Generator is generating power)
Charge indicator is off when the engine is running (Generator is generating power)
OK is displayed END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (ALTERNATOR STATUS)
Tip:Check the power generation status of the generator.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Alternator Status
Generator power generation status
Normal / Abnormal
Normal: Generator operation normal
-
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
Result
Proceed to
Normal is displayed
Abnormal is displayed
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the idling stop rate battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery condition
NG / OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Proceed to
NG is displayed
OK is displayed
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Idling Stop Rate
Rate of the idling stop time to the entire ignition switch ON time
Min.: 0%
Max.: 100%
-
-
Total Idling Stop Rate
Rate of total idling stop time
Min.: 0%
Max.: 100%
-
-
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
Permission Criteria
Tester Display
Conditions
Oper Permission (Battery)
Idling Stop Rate is 50% or less and Total Idling Stop Rate is 40% or less
Tip:Once the threshold is exceeded, stop and start will be permitted again once Idling Stop Rate reaches 47% or less and Total Idling Stop Rate reaches 40% or less.
OK is displayed END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (IDLING STOP RATE, TOTAL IDLING STOP RATE)
Tip:Check the idling stop rate.
Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate and Total Idling Stop Rate.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Idling Stop Rate
Rate of the idling stop time to the entire ignition switch ON time
Min.: 0%
Max.: 100%
-
-
Total Idling Stop Rate
Rate of total idling stop time
Min.: 0%
Max.: 100%
-
-
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
Result
Result
Proceed to
Idling Stop Rate is higher than 50% or Total Idling Stop Rate is 40% or higher
A
Idling Stop Rate is 50% or lower and Total Idling Stop Rate is 40% or lower
B
Tip:If Idling Stop Rate is higher than 50% or Total Idling Stop Rate is higher than 40%, turn the ignition switch off and leave the vehicle off for a while. After that, restart the engine. If the Data List item "Oper Permission (Battery)" still shows not permitted, the battery may be degraded or temporarily discharging. In that case, charge or replace the battery after checking the battery state.
A END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE 50% OR MORE OR TOTAL IDLING STOP RATE 40% OR MORE)
B CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE CURRENT SUM VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)
READ VALUE USING GTS (BATTERY TYPE)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
Check the "Battery Type" Data List Item.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Type
Set battery type
Specified / Other
Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
Check whether the battery is specified or not specified.
Result
Data List Battery Type Display
Equipped Battery
Proceed to
Other
Specified battery
A
Other
Non-specified battery
B
Specified
-
C
B EXPLAIN TO CUSTOMER THAT STOP AND START SYSTEM IS LIMITED TO PREVENT BATTERY MALFUNCTION WHEN A NON-SPECIFIED BATTERY IS USED
C CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE CURRENT SUM VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)
SWITCH BATTERY TYPE
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.
Powertrain > Engine and ECT > Utility
Tester Display
Switch Battery Type
Perform Switch Battery Type under Utility and set the Specified battery.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
Check that the "Battery Type" Data List item is set to "Specified".
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Type
Set battery type
Specified / Other
Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
Result
Proceed to
NEXT
NEXT END
READ VALUE USING GTS (HOOD COURTESY SWITCH)
Note:Before performing this step, check that the engine hood can be opened by pulling the hood lock control cable.
Tip:Check the engine hood courtesy switch (hood lock assembly).
Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Hood Courtesy Switch
Hood courtesy switch signal
ON / OFF
ON: Engine hood closed
OFF: Engine hood opened
-
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
Result
Proceed to
OK
NG
Tip:If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
OK END (STOP AND START CONTROL PROHIBITED DUE TO ENGINE START WITH ENGINE HOOD OPEN)