CLUTCH STROKE SENSOR(for C553A) INSPECTION
PROCEDURE
INSPECT CLUTCH STROKE SENSOR
Connect 3 dry-cell batteries (1.5 V each) in series.
*a
Main
*b
Sub
*c
Sensor Arm
*d
55°
*e
0°
*f
-55°
Connect a positive (+) lead from the batteries to terminal (A) and a negative (-) lead to terminal (B).
Turn the sensor arm and check the voltage between terminals (B) and (C).
Standard Voltage (Power source voltage at 4.5 V)
Sensor angle
Terminal (B)-(C) output voltage
55°
3.83 to 4.27 V
0°
2.01 to 2.49 V
-55°
0.23 to 0.67 V
Standard Voltage (Power source voltage at 4.7 to 5.3 V)
Sensor angle
Terminal (B)-(C) output voltage
55°
4.2 to 4.8 V
0°
2.2 to 2.8 V
-55°
0.2 to 0.8 V
Note:Do not apply more than 6 V.
Do not drop the clutch stroke sensor. If dropped, replace it with a new one.
If the voltage is not as specified, replace the clutch stroke sensor.