KNEE AIRBAG ASSEMBLY(for Sedan) INSTALLATION

PROCEDURE

  1. INSTALL LOWER NO. 1 INSTRUMENT PANEL AIRBAG ASSEMBLY

    1. Engage the 8 hooks to install the lower No. 1 instrument panel airbag assembly to the lower No. 1 instrument panel airbag door.

  2. INSTALL LOWER NO. 1 INSTRUMENT PANEL AIRBAG ASSEMBLY WITH DOOR

    1. Check that the ignition switch is off.

    2. Check that the cable is disconnected from the negative (-) battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    3. B324556C03

      *a

      Airbag Connector

      *b

      Airbag Connector Lock

      Connect the airbag connector to the lower No. 1 instrument panel airbag assembly with door.

      Note:

      When connecting any airbag connector, take care not to damage the airbag wire harness.

    4. Push in the airbag connector lock to install the airbag connector.

    5. Engage the 7 claws and 2 guides to temporarily install the lower No. 1 instrument panel airbag assembly with door.

    6. Install the 4 bolts.

      10 N*m

      102 kgf*cm

      7 ft.*lbf

      Note:

      Confirm that the lower No. 1 instrument panel airbag assembly with door is installed securely without any excessive gaps and is not protruding outward.

  3. INSTALL NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (w/ Instrument Panel Under Cover)

  4. INSTALL NO. 1 SWITCH HOLE BASE (for LHD)

  5. INSTALL NO. 1 SWITCH HOLE BASE (for RHD)

  6. INSTALL NO. 2 SWITCH HOLE BASE (for RHD without Entry and Start System)

  7. INSTALL INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY

  8. INSTALL NO. 1 INSTRUMENT PANEL REGISTER SUB-ASSEMBLY

  9. INSTALL NO. 2 INSTRUMENT PANEL GARNISH SUB-ASSEMBLY

  10. INSTALL LOWER INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY (for LHD)

  11. INSTALL LOWER INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY (for RHD)

  12. INSTALL NO. 2 INSTRUMENT PANEL REGISTER SUB-ASSEMBLY

  13. INSTALL CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY

  14. INSTALL NO. 1 INSTRUMENT PANEL GARNISH SUB-ASSEMBLY

  15. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick here

  16. PERFORM DIAGNOSTIC SYSTEM CHECK

  17. INSPECT SRS WARNING LIGHT