PROCEDURE
INSPECT VACUUM SWITCHING VALVE ASSEMBLY
Measure the resistance.
| *a | Component without harness connected (Vacuum Switching Valve Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the vacuum switching valve assembly.
| *a | Port (E) |
| *b | Port (F) |
| *c | Air |
| *d | Filter |
Check the operation of the vacuum switching valve assembly.
Using a vacuum pump, check that air flows from port (E) to the filter.
| Standard | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the vacuum switching valve assembly.
| *a | Port (E) |
| *b | Port (F) |
| *c | Air |
Apply battery voltage to the terminals and check that air flows from port (E) to port (F).
| Standard | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the vacuum switching valve assembly.