PARK ASSIST / MONITORING SERVICE DATA

Table 1. ULTRASONIC SENSOR (for Front)

Tester Connection

Condition

Specified Condition

1 (BI) - 5 (EI)

1 (BI) - 2 (BO)

Always

Below 1 Ω

3 (SI) - 4 (SO)

5 (EI) - 6 (EO)

Always

10 kΩ or higher

Table 2. ULTRASONIC SENSOR (for Rear)

Tester Connection

Condition

Specified Condition

1 (BI) - 5 (EI)

1 (BI) - 2 (BO)

Always

Below 1 Ω

3 (SI) - 4 (SO)

5 (EI) - 6 (EO)

Always

10 kΩ or higher

Table 3. CLEARANCE SONAR MAIN SWITCH

Tester Connection

Condition

Specified Condition

1 (ECU) - 9 (LAPB)

Clearance sonar main switch on

Below 1 Ω

Clearance sonar main switch off

10 kΩ or higher

Table 4. PANORAMIC VIEW MONITOR SWITCH

Tester Connection

Condition

Specified Condition

13 (E) - 20 (PVM)

Panoramic View Monitor Switch on

Below 1 Ω

Panoramic View Monitor Switch off

10 kΩ or higher