EGR BYPASS VALVE SWITCHING VALVE INSTALLATION

PROCEDURE

  1. INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY

    1. Using a 4 mm hexagon socket wrench, install the No. 1 vacuum switching valve assembly with the 2 bolts.

      5.0 N*m

      51 kgf*cm

      44 in.*lbf

    2. Connect the 2 vacuum transmitting hoses to the No. 1 vacuum switching valve assembly.

    3. Connect the No. 1 vacuum switching valve connector.

  2. INSTALL NO. 1 ENGINE COVER