ECM INSTALLATION

PROCEDURE

  1. INSTALL ECM

    1. Install the No. 2 ECM bracket to the ECM with the 2 screws.

      3.0 N*m

      31 kgf*cm

      27 in.*lbf

    2. Install the No. 1 ECM bracket to the ECM with the 2 screws.

      3.0 N*m

      31 kgf*cm

      27 in.*lbf

    3. Engage the guide and install the ECM with the 2 bolts.

      8.0 N*m

      82 kgf*cm

      71 in.*lbf

      Note:

      If the ECM has been struck or dropped, replace it.

    4. Connect the 2 ECM connectors and lower the 2 levers.

      Note:
      • When connecting the ECM connectors, make sure that the connecting parts of the ECM connectors are free of dirt, water or other foreign matter.

      • Be sure to securely connect the ECM connectors.

  2. INSTALL NO. 1 AIR CLEANER INLET

    1. Install the No. 1 air cleaner inlet with the bolt.

      7.0 N*m

      71 kgf*cm

      62 in.*lbf

  3. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

  4. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  5. INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

  6. INSTALL NO. 1 ENGINE COVER

  7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick hereClick here

  8. PERFORM REGISTRATION

  9. PERFORM INITIALIZATION