CONSTRUCTION
Models for Korea
The canister pump module consists of a vent valve, reference orifice, canister pressure sensor, leak detection pump and pump motor.
The vent valve switches the passages in accordance with the signals received from the ECM.
A DC type brushless motor is used for the pump motor.
A vane type leak detection pump is used.
| *1 | Canister Pump Module | *2 | Vent Valve |
| *3 | Reference Orifice | *4 | Canister Pressure Sensor |
| *5 | Pump Motor | *6 | Leak Detection Pump |
| *a | Fresh Air | *b | Cross Sectiom |
| *c | To Charcoal Canister Assembly | - | - |
Figure 1. Simplified Diagram
| *1 | Canister Pump Module | *2 | Leak Detection Pump and Pump Motor |
| *3 | Fliter | *4 | Canister Pressure Sensor |
| *5 | Reference Orifice [0.5 mm (0.02 in.) Diameter] | *6 | Vent Valve |
| *a | Fresh Air | *b | To Charcoal Canister Assembly |