OIL PRESSURE SWITCHING VALVE INSPECTION
PROCEDURE
INSPECT OIL PRESSURE SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
13 to 17 Ω
If the result is not as specified, replace the oil pressure switching valve assembly.
-
*a
Component without harness connected
(Oil Pressure Switching Valve Assembly)
Connect the positive (+) lead of the battery to terminal 1 and the negative (-) lead to terminal 2 and check that the operating sound of the oil pressure switching valve can be heard.
Note:Perform this test within 10 seconds to prevent the coil from burning out.
Always turn the voltage on and off at the battery, not the oil pressure switching valve assembly.
If the result is not as specified, replace the oil pressure switching valve assembly.