INSTALL GENERATOR ASSEMBLY
Install the generator with the bolt.
Connect the vacuum oil outlet hose.
Install 2 new gaskets and the vacuum pump hose with the union bolt.
Install the vacuum pump oil inlet hose with 2 new gaskets and the union bolt.
Attach the vacuum pump oil inlet hose to the cord clip.
Install the generator wire with the nut.
Attach the terminal cap.
Connect the generator connector.
INSTALL COMPRESSOR MOUNTING BRACKET (w/ Air Conditioning System)
Temporarily install the compressor mounting bracket with the 4 bolts.
Using several steps, uniformly install and tighten the 4 bolts in the sequence shown in the illustration.
Temporarily tighten the bolt and spacer.
INSTALL COOLER COMPRESSOR ASSEMBLY (w/ Air Conditioning System)
Install the compressor with the 4 bolts.
Connect the compressor connector.
INSTALL FAN BELT ADJUSTING BAR (w/o Air Conditioning System)
Install the fan belt adjusting bar with the 2 bolts.
Temporarily install the bolt.
INSTALL FAN & GENERATOR V BELT (w/o Air Conditioning System)
Install the V belt.
Using a bar, adjust the tension of the V belt.
Tighten the bolts A and B.
Check the deflection of the V belt Click here.
INSTALL FAN AND GENERATOR V BELT (w/ Air Conditioning System)
Rotate the V-ribbed belt tensioner pulley clockwise, and then install the fan and generator V belt.
Note
Make sure that the fan and generator V belt is set properly on each pulley.
Check that the indicator mark of the V-ribbed belt tensioner Click here.
INSTALL COOLER COMPRESSOR V BELT (w/ Air Conditioning System)
Install the V belt.
Tightening the bolt B, adjust the tension of the V belt.
Tighten nut A.
Check the tension of the V belt Click here.
INSTALL AIR CLEANER ASSEMBLY
Install the cleaner with the 2 bolts.
Connect the connector to the IAT sensor.
Connect the hose clamp.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
PERFORM INITIALIZATION
Perform initialization Click here.
Note
Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.