1AD-FTV STARTING SERVICE DATA

Table 1. GLOW PLUG

Tester Connection

Condition

Specified Condition

Glow plug terminal - Body ground

20°C (68°F)

0.28 Ω or higher

Table 2. STARTER ASSEMBLY (Standard Current)

Tester Connection

Condition

Specified Condition

Battery positive (+) terminal - Terminal 30 - Terminal 50

11.5 V

Below 190 A

Table 3. STARTER ARMATURE ASSEMBLY (Standard Resistance)

Tester Connection

Condition

Specified Condition

Segment - Segment

Always

Below 1 Ω

Segment - Coil core

Always

10 kΩ or higher

Table 4. STARTER ARMATURE ASSEMBLY

Standard Diameter

35.0 mm (1.37 in.)

Minimum Diameter

34.0 mm (1.34 in.)

Maximum runout

0.05 mm (0.00197 in.)

Standard undercut depth

0.7 mm (0.0276 in.)

Minimum undercut depth

0.2 mm (0.00787 in.)

Table 5. STARTER YOKE ASSEMBLY (Standard Resistance)

Tester Connection

Condition

Specified Condition

Lead wire - Brush

Always

Below 1 Ω

Brush - Starter yoke body

Always

10 kΩ or higher

Table 6. BRUSH

Standard Length

15.0 mm (0.591 in.)

Minimum Length

9.0 mm (0.354 in.)

Table 7. STARTER BRUSH HOLDER ASSEMBLY

Standard Resistance

10 kΩ or higher

Brush Spring

Standard Spring Installed Load

21.5 to 27.5 N (2 to 3 kgf, 4.8 to 6.2 lbf)

Minimum Spring Installed Load

12.3 N (1 kgf, 2.8 lbf)

Table 8. STARTER MAGNETIC SWITCH ASSEMBLY (Standard Resistance)

Tester Connection

Condition

Specified Condition

Terminal 50 - Terminal C

Always

Below 1 Ω

Terminal 50 - Switch body

Always

Below 2 Ω

Table 9. STARTER RELAY (ST)

Tester Connection

Condition

Specified Condition

3 - 5

Battery voltage not applied to terminals 1 and 2

10 kΩ or higher

Battery voltage applided to terminals 1 and 2

Below 1 Ω

Table 10. GLOW PLUG RELAY

Tester Connection

Condition

Specified Condition

1 - 2

Battery voltage not applied to terminals 3 and 4

10 kΩ or higher

Battery voltage applided to terminals 3 and 4

Below 1 Ω