PROCEDURE
PRECAUTION
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
REMOVE DECK BOARD ASSEMBLY
REMOVE NO. 1 DECK BOARD
REMOVE NO. 2 DECK BOARD
REMOVE REAR DECK FLOOR BOX
REMOVE DECK FLOOR BOX RH
DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE INTEGRATION CONTROL AND PANEL
REMOVE INSTRUMENT PANEL BOX ASSEMBLY
REMOVE CENTER INSTRUMENT PANEL REGISTER ASSEMBLY
REMOVE LOWER CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
REMOVE NO. 2 HEATER TO REGISTER DUCT SUB-ASSEMBLY
REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
REMOVE COMBINATION METER SUB-ASSEMBLY
| *1 | Protective Tape |
Apply protective tape to the areas shown in the illustration.
Remove the 4 screws.
Move the combination meter sub-assembly as shown in the illustration.
Disengage the clamp.
Disconnect each connector to remove the combination meter sub-assembly.