AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR (for VALEO Made)


    1. Remove the vinyl tape from the cooler refrigerant liquid pipe A.

    2. Sufficiently apply compressor oil to a new air conditioner pressure sensor and the fitting surface of the air conditioner pressure sensor.

      Compressor Oil
      VC100YF or equivalent
    3. A001VQCC01
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor as shown in the illustration.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    4. Connect the connector.

  2. INSTALL AIR CONDITIONER PRESSURE SENSOR (for DENSO Made)


    1. Remove the vinyl tape from the cooler refrigerant liquid pipe A.

    2. Sufficiently apply compressor oil to a new air conditioner pressure sensor and the fitting surface of the air conditioner pressure sensor.

      Compressor Oil
      ND-OIL 8 or equivalent
    3. A001VMIC02
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor as shown in the illustration.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. Connect the connector.

  3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFC-134a(R134a))

    Click here

  4. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFO-1234yf(R1234yf))

    Click here

  5. WARM UP WARM UP ENGINE (for HFC-134a(R134a))

    Click here

  6. WARM UP WARM UP ENGINE (for HFO-1234yf(R1234yf))

    Click here

  7. INSPECT FOR REFRIGERANT LEAK (for HFC-134a(R134a))

    Click here

  8. INSPECT FOR REFRIGERANT LEAK (for HFO-1234yf(R1234yf))

    Click here