FUEL PUMP INSPECTION

PROCEDURE

  1. INSPECT FUEL PUMP

    A316349E02
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      4 - 5

      20°C (68°F)

      0.2 to 3.0 Ω

      Table 1. Text in Illustration

      *a

      Component without harness connected

      (Fuel Suction with Pump and Gauge Tube Assembly)

      If the result is not as specified, replace the fuel suction with pump and gauge tube assembly.

    2. Inspect the operation of the fuel pump.

      1. A316350E02

        Connect the positive (+) lead of the battery to terminal 4 of the connector, and the negative (-) lead to terminal 5. Check that the fuel pump operates.

        Table 2. Text in Illustration

        *a

        Component without harness connected

        (Fuel Suction with Pump and Gauge Tube Assembly)

        If the pump does not operate, replace the fuel suction with pump and gauge tube assembly.

        Note:
        • This test must be performed within 10 seconds to prevent the coil from burning out.

        • Keep the fuel pump as far away from the battery as possible.

        • Always turn the voltage on and off on the battery side, not the fuel pump side.