HEATED OXYGEN SENSOR(for Sensor 2) INSPECTION
PROCEDURE
INSPECT HEATED OXYGEN SENSOR (Sensor 2)
-
*a
Component without harness connected
(Heated Oxygen Sensor (Sensor 2))
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (+B) - 2 (HT1B)
Always
2.7 to 4.7 Ω
If the result is not as specified, replace the heated oxygen sensor (sensor 2).
-