DESCRIPTION
The ECM calculates an appropriate cooling fan speed based on the engine coolant temperature, air conditioning switch condition, refrigerant pressure, engine speed and vehicle speed. The cooling fan ECUs control each cooling fan speed based on the duty cycle calculated by the ECM. By optimally controlling the cooling fan speed via the cooling fan ECUs based on the conditions of the vehicle, the ECM can achieve both high cooling performance and quietness.
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the ECM, refer to Service Bulletin.
PROCEDURE
PERFORM ACTIVE TEST USING GTS (CONTROL THE ENGINE COOLING FAN DUTY RATIO)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Control the Engine Cooling Fan Duty Ratio.
| Tester Display |
|---|
| Control the Engine Cooling Fan Duty Ratio |
Perform the Active Test according to the display on the GTS.
| OK | ||||||
|---|---|---|---|---|---|---|
|
| Result | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
CHECK COOLING FAN SYSTEM (FAN RH) Click here |
| D |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH - ECM) Click here |
| E |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU RH - ECM) Click here |
| B |
|
CHECK COOLING FAN SYSTEM (FAN LH)
Disconnect the A46 ECM connector.
Turn the engine switch on (IG).
Check the operation of the cooling fan LH.
| OK |
|---|
| The cooling fan LH operates. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE ECM Click here |
| NG |
|
INSPECT COOLING FAN MOTOR LH
Inspect the cooling fan motor LH.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE COOLING FAN MOTOR LH Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH POWER SOURCE)
Disconnect the A5 cooling fan ECU LH connector.
Turn the engine switch on (IG).
| *a | Front view of wire harness connector (to Cooling Fan ECU LH) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH - BODY GROUND) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH AND COOLING FAN ECU RH - ECM)
Disconnect the A46 ECM connector.
Disconnect the A5 cooling fan ECU LH connector.
Disconnect the A6 cooling fan ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE COOLING FAN ECU LH |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU LH AND COOLING FAN ECU RH - ECM) |
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH - BODY GROUND)
Disconnect the A5 cooling fan ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU LH - BODY GROUND) |
| OK |
|
INSPECT FAN NO. 1 RELAY
Inspect the FAN NO. 1 relay.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE FAN NO. 1 RELAY |
| OK |
|
CHECK HARNESS AND CONNECTOR (FAN NO. 1 RELAY POWER SOURCE CIRCUIT)
Remove the FAN NO. 1 relay from the No. 1 engine room relay block and No. 1 junction block assembly.
Turn the engine switch on (IG).
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | FAN NO. 1 Relay |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (FAN NO. 1 RELAY POWER SOURCE CIRCUIT) |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH - FAN NO. 1 RELAY)
Disconnect the A5 cooling fan ECU LH connector.
Remove the FAN NO. 1 relay from the No. 1 engine room relay block and No. 1 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (FAN NO. 1 RELAY - BODY GROUND) |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU LH - FAN NO. 1 RELAY) |
CHECK COOLING FAN SYSTEM (FAN RH)
Disconnect the A46 ECM connector.
Turn the engine switch on (IG).
Check the operation of the cooling fan RH.
| OK |
|---|
| The cooling fan RH operates. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE ECM Click here |
| NG |
|
INSPECT COOLING FAN MOTOR RH
Inspect the cooling fan motor RH.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE COOLING FAN MOTOR RH Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU RH POWER SOURCE)
Disconnect the A6 cooling fan ECU RH connector.
Turn the engine switch on (IG).
| *a | Front view of wire harness connector (to Cooling Fan ECU RH) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU RH - BODY GROUND) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH AND COOLING FAN ECU RH - ECM)
Disconnect the A46 ECM connector.
Disconnect the A5 cooling fan ECU LH connector.
Disconnect the A6 cooling fan ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE COOLING FAN ECU RH |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU LH AND COOLING FAN ECU RH - ECM) |
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU RH - BODY GROUND)
Disconnect the A6 cooling fan ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU RH - BODY GROUND) |
| OK |
|
INSPECT FAN NO. 2 RELAY
Inspect the FAN NO. 2 relay.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE FAN NO. 2 RELAY |
| OK |
|
CHECK HARNESS AND CONNECTOR (FAN NO. 2 RELAY POWER SOURCE CIRCUIT)
Remove the FAN NO. 2 relay from the No. 1 engine room relay block and No. 1 junction block assembly.
Turn the engine switch on (IG).
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | FAN NO. 2 Relay |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (FAN NO. 2 RELAY POWER SOURCE CIRCUIT) |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU RH - FAN NO. 2 RELAY)
Disconnect the A6 cooling fan ECU RH connector.
Remove the FAN NO. 2 relay from the No. 1 engine room relay block and No. 1 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (FAN NO. 2 RELAY - BODY GROUND) |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU RH - FAN NO. 2 RELAY) |
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU LH - ECM)
Disconnect the A46 ECM connector.
Disconnect the A5 cooling fan ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU LH - ECM) |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN MOTOR LH - BODY GROUND)
Disconnect the z1 cooling fan motor LH connector.
| *a | Component without harness connected (Cooling Fan Motor LH) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE COOLING FAN ECU LH |
| NG |
|
REPLACE COOLING FAN MOTOR LH Click here |
CHECK HARNESS AND CONNECTOR (COOLING FAN ECU RH - ECM)
Disconnect the A46 ECM connector.
Disconnect the A6 cooling fan ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (COOLING FAN ECU RH - ECM) |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLING FAN MOTOR RH - BODY GROUND)
Disconnect the z10 cooling fan motor RH connector.
| *a | Component without harness connected (Cooling Fan Motor RH) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE COOLING FAN ECU RH |
| NG |
|
REPLACE COOLING FAN MOTOR RH Click here |