ТОПЛИВНЫЙ ФИЛЬТР ПРОВЕРКА


  1. LEVEL WARNING SWITCH (FUEL SEDIMENTER WARNING SWITCH)


    1. Inspect level warning switch


      1. B007TLKE01

        Using an ohmmeter, measure the resistance between the terminals

        Standard Resistance
        Tester connection Condition Specified Value
        1 - 2 Float upper end position Below 1 Ω
        1 - 2 Float lower end position 1 MΩ or more