SELECT STROKE SENSOR INSPECTION
PROCEDURE
INSPECT SELECT STROKE SENSOR
-
*1
Sensor Arm
*a
Component without harness connected
(Select Stroke Sensor)
*b
Main
Check the output voltage of the select stroke sensor (main circuit).
Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries to the sensor.
Connect the batteries in series.
Connect a positive (+) lead from the batteries to terminal 3, and a negative (-) lead to terminal 2.
Measure the voltage according to the value(s) in the table below.
Standard Voltage (combined dry cell battery voltage of 4.5 V)
Tester Connection
Condition (SensorAngle)
Specified Condition
1 (VSL1) - 2 (E2L1)
55°
3.83 to 4.27 V
0°
2.01 to 2.49 V
-55°
0.23 to 0.67 V
Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)
Tester Connection
Condition (SensorAngle)
Specified Condition
1 (VSL1) - 2 (E2L1)
55°
4.2 to 4.8 V
0°
2.2 to 2.8 V
-55°
0.2 to 0.8 V
Note:Do not apply more than 6 V.
If the select stroke sensor has been dropped or subjected to a severe impact, replace it.
If the result is not as specified, replace the select stroke sensor.
-
*1
Sensor Arm
*a
Component without harness connected
(Select Stroke Sensor)
*b
Sub
Check the output voltage of the select stroke sensor (sub circuit).
Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries to the sensor.
Connect the batteries in series.
Connect a positive (+) lead from the batteries to terminal 6, and a negative (-) lead terminal 5.
Measure the voltage according to the value(s) in the table below.
Standard Voltage (combined dry cell battery voltage of 4.5 V)
Tester Connection
Condition (SensorAngle)
Specified Condition
4 (VSL2) - 5 (E2L2)
55°
3.83 to 4.27 V
0°
2.01 to 2.49 V
-55°
0.23 to 0.67 V
Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)
Tester Connection
Condition (SensorAngle)
Specified Condition
4 (VSL2) - 5 (E2L2)
55°
4.2 to 4.8 V
0°
2.2 to 2.8 V
-55°
0.2 to 0.8 V
Note:Do not apply more than 6 V.
If the select stroke sensor has been dropped or subjected to a severe impact, replace it.
If the result is not as specified, replace the select stroke sensor.
-