SELECT STROKE SENSOR INSTALLATION

PROCEDURE

  1. INSTALL SELECT STROKE SENSOR

    1. Apply MP grease to a new O-ring.

    2. Install the O-ring to the select stroke sensor.

    3. C274892

      Set the select stroke sensor so that the sensor side and actuator side sensor arms are positioned as shown in the illustration.

    4. Turn the select stroke sensor clockwise.

    5. Install the 2 screws.

      1.3 N*m

      13 kgf*cm

      12 in.*lbf

    6. Connect the select stroke sensor connector.

    7. Connect the 2 wire harness clamps.

  2. INSTALL AIR CLEANER BRACKET

  3. INSTALL FUEL FILTER SUPPORT

  4. CONNECT ENGINE WIRE

  5. INSTALL FUEL FILTER ASSEMBLY

  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick here

  7. PERFORM INITIALIZATION OF MULTI-MODE MANUAL TRANSAXLE SYSTEM

  8. PERFORM LEARNING OF MULTI-MODE MANUAL TRANSAXLE SYSTEM

  9. PERFORM SYNCHRONIZATION POSITION CALIBRATION