SELECT STROKE SENSOR INSTALLATION
PROCEDURE
INSTALL SELECT STROKE SENSOR
Apply MP grease to a new O-ring.
Install the O-ring to the select stroke sensor.
-
Set the select stroke sensor so that the sensor side and actuator side sensor arms are positioned as shown in the illustration.
Turn the select stroke sensor clockwise.
Install the 2 screws.
1.3 N*m
13 kgf*cm
12 in.*lbf
Connect the select stroke sensor connector.
Connect the 2 wire harness clamps.
INSTALL AIR CLEANER BRACKET
INSTALL FUEL FILTER SUPPORT
CONNECT ENGINE WIRE
INSTALL FUEL FILTER ASSEMBLY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
PERFORM INITIALIZATION OF MULTI-MODE MANUAL TRANSAXLE SYSTEM
PERFORM LEARNING OF MULTI-MODE MANUAL TRANSAXLE SYSTEM
PERFORM SYNCHRONIZATION POSITION CALIBRATION