3ZR-FAE COOLING SERVICE DATA

Table 1. COOLANT

Item

Standard Capacity

Classification

for Manual Transaxle

5.8 liters (6.1 US qts, 5.1 Imp. qts)

Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).

for CVT

5.9 liters (6.2 US qts, 5.2 Imp. qts)

Table 2. THERMOSTAT

Thermostat

Valve opening temperature

78 to 82°C (172 to 180°F)

Valve lift (for Type A)

10 mm (0.394 in.) or more at 93°C (199°F)

Valve lift (for Type B)

10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)

Table 3. COOLING FAN MOTOR

Cooling fan motor

2 (+)

Standard Current

5.5 to 7.5 A

No. 2 cooling fan motor

2 (+)

Standard Current

5.5 to 7.5 A

Table 4. RADIATOR

Reservoir cap

Standard Judgment Criterion

Standard value

(for brand-new cap)

93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)

Minimum standard value

(for used cap)

79 kPa (0.8 kgf/cm2, 11.4 psi)