BLIND SPOT MONITOR SYSTEM Power Source Circuit

DESCRIPTION

This circuit provides power to operate the blind spot monitor sensor.

WIRING DIAGRAM

A01REDSE05

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH POWER SOURCE)


    1. Disconnect the X2 blind spot monitor sensor LH connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      X2-5 (BLB) - Body ground Engine switch on (IG)

      11 to 14 V*1

      10.5 to 16 V*2

      X2-5 (BLB) - Body ground Engine switch off Below 1 V

      • *1: w/o Stop and Start System

      • *2: w/ Stop and Start System

      Result
      Result Proceed to
      OK A
      NG (w/o Stop and Start System) B
      NG (w/ Stop and Start System) C

    B
    C
    A
  2. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      X2-10 (BLGD) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH POWER SOURCE)


    1. Disconnect the W2 blind spot monitor sensor RH connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      W2-5 (BRB) - Body ground Engine switch on (IG)

      11 to 14 V*1

      10.5 to 16 V*2

      W2-5 (BRB) - Body ground Engine switch off Below 1 V

      • *1: w/o Stop and Start System

      • *2: w/ Stop and Start System

      Result
      Result Proceed to
      OK A
      NG (w/o Stop and Start System) B
      NG (w/ Stop and Start System) C

    B
    C
    A
  4. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      W2-10 (BRGD) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG