PROCEDURE
INSPECT THERMOSTAT
Tech Tips
The valve opening temperature is inscribed on the thermostat.
Check that the valve is fully closed when the thermostat is at a low temperature (below 77°C (171°F)).
If the valve is not fully closed, replace the thermostat.
Immerse the thermostat in water, and then gradually heat the water.
Check that the valve opens at the specified temperature.
| Standard Valve Opening Temperature |
|---|
| 80 to 84°C (176 to 183°F) |
If the result is not as specified, replace the thermostat.
| *a | Valve Lift |
Check the valve lift.
| Standard Valve Lift |
|---|
| 10 to 12 mm (0.394 to 0.472 in.) at 95°C (203°F) |
If the result is not as specified, replace the thermostat.