AIR CONDITIONING PRESSURE SENSOR INSTALLATION
PROCEDURE
INSTALL AIR CONDITIONER PRESSURE SENSOR
Remove the vinyl tape from the air conditioner tube and accessory assembly and the connecting part of the air conditioner pressure sensor.
Apply sufficient compressor oil to the O-ring of a new air conditioner pressure sensor and the connecting surface.
Refrigerant
Compressor Oil
HFC-134a (R134a)
ND-OIL 8 or equivalent
HFO-1234yf (R1234yf)
ND-OIL 12 or equivalent
-
*a
Turn
*b
Hold
Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.
11 N*m
112 kgf*cm
8 ft.*lbf
Connect the connector.
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
WARM UP ENGINE
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
INSPECT FOR REFRIGERANT LEAK
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):