PRE-CRASH SAFETY SYSTEM WARNING BUZZER INSTALLATION

PROCEDURE

  1. INSTALL PRE-CRASH SAFETY CITY BUZZER

    Note:

    If the pre-crash safety city buzzer has been struck or dropped, replace it with a new one.

    1. E319779

      Engage the clamp to install the pre-crash safety city buzzer.

    2. Connect the connector.

      Tip:

      Make sure the connector and terminals are not deformed or corroded.

  2. INSTALL LOWER INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY (for LHD)

  3. INSTALL LOWER INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY (for RHD)