COMPRESSOR(for 1WW) REMOVAL

PROCEDURE

  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    1. for HFC-134a(R134a):

      (Click here)

    2. for HFO-1234yf(R1234yf):

      (Click here)

  2. REMOVE RADIATOR ASSEMBLY

  3. REMOVE FAN AND GENERATOR V BELT

  4. DISCONNECT SUCTION HOSE SUB-ASSEMBLY

    1. E286590

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

    2. Remove the O-ring from the suction hose sub-assembly.

  5. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY

    1. E286591

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

    2. Remove the O-ring from the discharge hose sub-assembly.

  6. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY

    1. E286592

      Disconnect the connector and detach the harness clamp.

    2. Remove the bolt, 2 nuts and compressor assembly with pulley.

    3. E286593

      Using an E8 "TORX" socket wrench, remove the 2 stud bolts.

    4. Remove the compressor pin.

      Note:

      It is not necessary to remove a compressor pin unless it being replaced.