AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) CUSTOMIZE PARAMETERS
1. CUSTOMIZE AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)
Customizing with the GTS
Tip:The following items can be customized.
Note:When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
Connect the GTS.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Customize Setting / Air Conditioner.
Select the setting by referring to the table below.
Air Conditioner
Tester Display
Description
Default
Setting
ECU
Set Temperature Shift
Function to perform control with the shifted temperature versus the displayed temperature
Normal
00001:-2C,00010:-1C,00100:Normal,01000:+1C,10000:+2C
Air Conditioning Amplifier Assembly
Evaporator Control
Function to set the evaporator control to the AUTOMATIC position (AUTO) to save power or to the coldest position (MANUAL) to dehumidify the air and to prevent the windows from fogging up
Automatic
0:Automatic,1:Manual
Air Conditioning Amplifier Assembly
Compressor Mode
Function to turn the air conditioning on automatically by pressing the AUTO button when the blower is on and the air conditioning is off
Automatic
0:Automatic,1:Manual
Air Conditioning Amplifier Assembly
Air Inlet Mode
Function to change the mode automatically to RECIRCULATION mode in cases when the air conditioning is turned on to cool the cabin down quickly
Automatic
0:Automatic,1:Manual
Air Conditioning Amplifier Assembly
Foot/DEF Auto Mode
Function to turn the airflow from FOOT/DEF ON automatically when AUTO MODE is ON
ON
0:ON,1:OFF
Air Conditioning Amplifier Assembly
Foot/DEF Automatic Blow Up Function
Function to increase the blower level automatically when the defroster is ON
ON
0:ON,1:OFF
Air Conditioning Amplifier Assembly
ECO MODE Cancel
Function to cancel the ECO mode drive when item is ON
OFF
0:OFF,1:ON
Air Conditioning Amplifier Assembly
Refrigerant Shortage Check
Function to cancel the refrigerant gas volume check (check performed during normal operation) when item is OFF
ON
0:ON,1:OFF
Air Conditioning Amplifier Assembly
Fan speed increment control
Function to define how fast the air conditioning blower goes to target speed when first activating the air conditioning
Normal
001:Slow,010:Normal,100:Fast
Air Conditioning Amplifier Assembly
Blower Operation Setting (Stop&Start)
This customization is an item that sets the blower level to "1" while the Stop and Start System is controlling the idling stop
Blower OFF
0:Blower OFF,1:Blower Level 1
Air Conditioning Amplifier Assembly