SPEED LIMITER SYSTEM TERMINALS OF ECM

  1. CHECK ECM (for 2WW)

    A318632E04
    Tip:

    The standard voltage between each pair of the ECM terminals is shown in the table below. The appropriate conditions for checking each pair of the terminals are also indicated.

    The result of checks should be compared with the standard voltage for that pair of terminals, and displayed in the "Specified Condition" column.

    The illustration above can be used as a reference to identify the ECM terminal locations.

    Table 1. for 2WW:

    Terminal No. (Symbol)

    Wiring Color

    Terminal Description

    Condition

    Specified Condition

    A62-4 (E1) - Body ground

    W-B - Body ground

    Ground

    Always

    Below 1 Ω

    A62-15 (BATT) - A62-4 (E1)

    W - W-B

    Power source circuit

    Always

    11 to 14 V

    A62-37 (IGSW) - A62-4 (E1)

    B - W-B

    IG power source circuit

    Ignition switch ON

    11 to 14 V

    Ignition switch off

    Below 1 V

    A62-49 (ASLM) - A62-42 (ECCS)

    P - BR

    Speed limiter switch signal

    Speed limiter switch on

    Below 1 Ω

    Speed limiter switch off

    10 kΩ or higher

  2. CHECK ECM (for 3ZR-FAE)

    A342925E06
    Tip:

    The standard normal voltage between each pair of the ECM terminals is shown in the table below. The appropriate conditions for checking each pair of the terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of the terminals, which is displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.

    Table 2. for 3ZR-FAE:

    Terminal No. (Symbol)

    Wiring Color

    Terminal Description

    Condition

    Specified Condition

    A62-1 (BATT) - B93-59 (E1)

    W - BR

    Power source circuit

    Always

    11 to 14 V

    A62-6 (IGSW) - B93-59 (E1)

    B - BR

    Ignition switch signal

    Ignition switch ON

    11 to 14 V

    A62-20 (ASLM) - A62-35 (ECCS)

    P - BR

    Speed limiter switch signal

    Speed limiter switch on

    Below 1 Ω

    Speed limiter switch off

    10 kΩ or higher

    B93-59 (E1) - Body ground

    BR - Body ground

    Ground

    Always

    Below 1 Ω