AUTOMATIC TRANSMISSION SYSTEM (for 1KD-FTV), Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P0894 Click here.

DTC Code DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic)
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • TCM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve SLT circuit is detected, the TCM interprets this as a fault. The TCM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

A01E214E55

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A01E0VEE51

      Disconnect the E1 transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      14 (SLT+) - 6 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      14 (SLT+) - Body ground 20°C (68°F) 10 kΩ or higher
      6 (SLT-) - Body ground 20°C (68°F) 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    1. A01E2RLE31

      Disconnect the T19 TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T19-20 (SLT+) - T19-19 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      T19-20 (SLT+) - Body ground 20°C (68°F) 10 kΩ or higher
      T19-19 (SLT-) - Body ground 20°C (68°F) 10 kΩ or higher

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01DWP5E01

      Remove the shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

    NG
    OK