CAMSHAFT OIL CONTROL VALVE REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    CAUTION:

    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.

  2. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    1. A01E1BZ

      Disconnect the oil control valve connector.

    2. Remove the bolt and oil control valve.

    3. Remove the O-ring from the oil control valve.