PROCEDURE
INSTALL MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
Note
Make sure that no foreign matter gets on the connecting surfaces.
Do not touch the ECU connector.
| *1 | Housing Sidewall |
| *a | 20° or more |
Insert the main body ECU (multiplex network body ECU) up to the position where it contacts the housing sidewall of the guide as shown in the illustration.
Tech Tips
Make sure to keep the angle 20° or more as shown in the illustration.
| *1 | Housing Sidewall |
| *2 | Junction Block Fuse |
Slide the guide of the main body ECU (multiplex network body ECU) along the housing sidewall so that it contacts the junction block fuses as shown in the illustration.
| *1 | Side A Contact Portion |
While keeping the main body ECU (multiplex network body ECU) in contact with side A of the junction block (axis of rotation), rotate it downward as shown in the illustration.
| *1 | Push Area |
Press the push area until the claw engages to install the main body ECU (multiplex network body ECU).
Note
Make sure to press only the push area.
Confirm the engagement of the main body ECU (multiplex network body ECU) and junction block by listening for the lock sound.
Tech Tips
If a lock sound cannot be heard, visually check the lock part engagement. The engagement can also be confirmed if the main body ECU (multiplex network body ECU) and junction block are flush.
INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Engage the claw to connect the connector as shown in the illustration.
Note
Be sure to engage the claw securely.
Engage the claw to lock the connector lock as shown in the illustration.
Engage the claw to connect the connector as shown in the illustration.
Note
Be sure to engage the claw securely.
for LHD:
Engage the 2 claws to connect the wiring harness protector.
Install the instrument panel junction block assembly with the bolt and nut.
Engage the claw to connect the connector as shown in the illustration.
Note
Be sure to engage the claw securely.
Engage the claw to connect the connector as shown in the illustration.
Note
Be sure to engage the claw securely.
Connect each connector.
for RHD:
Engage the clamp.
Install the instrument panel junction block assembly with the bolt and nut.
Engage the clamp.
Connect each connector.
Engage the 2 claws to connect the 2 connectors as shown in the illustration.
INSTALL LOWER INSTRUMENT PANEL FINISH PANEL ASSEMBLY (for LHD)
INSTALL NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (for LHD)
INSTALL ECU INTEGRATION BOX LH (for RHD)
INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY (for RHD)
Tech Tips
Use the same procedure as for LHD Click here.
INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (for RHD)
Tech Tips
Use the same procedure as for LHD Click here.
CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
INSTALL DECK FLOOR BOX RH
INSTALL REAR DECK FLOOR BOX
INSTALL NO. 1 DECK BOARD
INSTALL NO. 2 DECK BOARD
INSTALL DECK BOARD ASSEMBLY