COMBINATION METER DISASSEMBLY

CAUTION / NOTICE / HINT

Note

When disassembling the combination meter sub-assembly, eliminate static electricity by touching the vehicle body to prevent components from being damaged.

PROCEDURE


  1. REMOVE COMBINATION METER GLASS


    1. A005BDW

      Remove the 2 screws.

    2. A005EFU

      Disengage the 8 claws and remove the combination meter glass.

  2. REMOVE NO. 2 COMBINATION METER COVER (w/ Multi-information Display)


    1. A005BFA

      Remove the 2 screws.

    2. A005EX3

      Disengage the 10 claws and remove the No. 2 combination meter cover.

  3. REMOVE NO. 1 COMBINATION METER LENS (w/ Multi-information Display)


    1. A005CTJ

      Disengage the 2 guides and remove the No. 1 combination meter lens.

  4. REMOVE NO. 1 COMBINATION METER COVER


    1. A005D78

      Remove the 8 screws.

    2. A005E7Y

      Disengage the 4 claws and remove the No. 1 combination meter cover.

  5. REMOVE METER CIRCUIT PLATE (w/o Multi-information Display)


    1. A005AC6

      Remove the meter circuit plate.