PROCEDURE
INSTALL CHARCOAL CANISTER LEAK DETECTION PUMP SUB-ASSEMBLY
Tech Tips
Only perform this procedure when replacement of the charcoal canister leak detection pump sub-assembly is necessary.
Engage the 2 claws to install a new charcoal canister leak detection pump sub-assembly to the charcoal canister sub-assembly.
Note
Do not allow foreign matter such as grease, oil or water to adhere to the O-rings.
Ensure that the claws are engaged properly.
Install the No. 2 charcoal canister sub-assembly with the 3 nuts.
| *a | Retainer |
|
Push in |
Push in the fuel tank vent hose sub-assembly onto the charcoal canister sub-assembly and push in the retainer to engage the lock claws.
Note
Check that there are no scratches or foreign matter around the connecting parts of the tube connector and pipe (charcoal canister sub-assembly) before performing this work.
After connecting the fuel tank vent hose sub-assembly, check that the fuel tank vent hose sub-assembly is securely connected by pulling on the tube connector.
Install the charcoal canister cap.
INSTALL CANISTER (CHARCOAL CANISTER ASSEMBLY)
Engage the clip and install the canister (charcoal canister assembly) to the vehicle body with the bolt and 3 nuts.
Connect the charcoal canister leak detection pump sub-assembly connector and engage the clamp.
Connect the purge line hose to the fuel tube and slide the clip to secure it.
Push in the air line tube to the pipe (charcoal canister leak detection pump sub-assembly) until the air line tube makes a "click" sound.
Note
Check that there are no scratches or foreign matter around the connecting parts of the tube connector and pipe (charcoal canister leak detection pump sub-assembly) before performing this work.
After connecting the air line tube, check that the air line tube is securely connected by pulling on the tube connector.
| *a | Retainer |
|
Push in |
Push the vent line hose onto the canister (charcoal canister assembly) and push in the retainer to engage the lock claws.
Note
Check that there are no scratches or foreign matter around the connecting parts of the tube connector and pipe (canister (charcoal canister assembly)) before performing this work.
After connecting the vent line hose, check that the vent line hose is securely connected by pulling on the tube connector.
INSTALL CHARCOAL CANISTER PROTECTOR
Install the charcoal canister protector with the 4 bolts and 3 nuts.
INSTALL TAIL EXHAUST PIPE ASSEMBLY
Install 2 new exhaust pipe gaskets to the center exhaust pipe assembly (TWC: Rear Catalyst) and tail exhaust pipe assembly.
Connect the tail exhaust pipe assembly to the 2 exhaust pipe supports.
Install the tail exhaust pipe assembly to the center exhaust pipe assembly (TWC: Rear Catalyst) and No. 2 tail exhaust pipe assembly with the 4 bolts.
INSPECT FOR EXHAUST GAS LEAK