SMOG VENTILATION SENSOR INSPECTION
PROCEDURE
INSPECT SMOG VENTILATION SENSOR
-
*a
Component without harness connected
(Smog Ventilation Sensor)
HC, CO
Connect the battery positive (+) lead to terminal 3 (IG) and the negative (-) lead to terminal 6 (E).
Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor and measure the resistance between terminals 1 (SG) and 2 (DGS).
OK
When the sensor is exposed to the exhaust gas, the resistance increases.
Tip:The resistance before blowing exhaust gas is 10 kΩ to 40 kΩ.
If the result is not as specified, replace the smog ventilation sensor.
-
*a
Component without harness connected
(Smog Ventilation Sensor)
NOx
Connect the battery positive (+) lead to terminal 3 (IG) and the negative (-) lead to terminal 6 (E).
Allow exhaust gas (NOx) to travel to the sensing portion of the smog ventilation sensor and measure the resistance between terminals 1 (SG) and 4 (DGS1).
OK
When the sensor is exposed to the exhaust gas, the resistance increases.
Tip:The resistance before blowing exhaust gas is 2.5 kΩ to 40 kΩ.
If the result is not as specified, replace the smog ventilation sensor.
-