LIGHTING SYSTEM Hazard Warning Switch Circuit

DESCRIPTION

The combination meter receives hazard warning signal switch information signals and illuminates the hazard warning light(s).

WIRING DIAGRAM

B007V40E01

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING GTS (HAZARD WARNING SIGNAL SWITCH)


    1. Using the GTS, read the Data List Click here.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard warning signal switch signal / ON or OFF

      ON: Hazard warning signal switch on

      OFF: Hazard warning signal switch off

      -
      OK
      Normal conditions listed above are displayed.

    NG
    OK
  2. INSPECT HAZARD WARNING SIGNAL SWITCH


    1. Remove the hazard warning signal switch Click here.

    2. Inspect the hazard warning signal switch Click here.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH - COMBINATION METER AND BODY GROUND)


    1. Disconnect the H9 hazard warning signal switch connector.

    2. Disconnect the H20 combination meter connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H9-3 - H20-28 (HAZ) Always Below 1 Ω
      H9-4 - Body ground Always Below 1 Ω
      H9-3 - Body ground Always 10 kΩ or higher

    NG
    OK