AIR CONDITIONING SYSTEM(except Automatic Air Conditioning System) PROBLEM SYMPTOMS TABLE
Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
Inspect the fuses and relays related to this system before inspecting the suspected areas below.
Symptom |
Suspected Area |
Link |
|---|---|---|
All functions of the air conditioning system do not operate |
IG power source circuit |
|
Air conditioning control assembly |
||
Air flow control: No blower operation |
Blower motor circuit |
|
Air filter sub-assembly*3 |
||
Air conditioning control assembly |
||
Air flow control: No blower control |
Blower motor circuit |
|
Air filter sub-assembly*3 |
||
Air conditioning control assembly |
||
Air flow control: Insufficient air flow |
Blower motor circuit |
|
Air filter sub-assembly*3 |
||
Air inlet damper control cable sub-assembly |
||
Air conditioning radiator assembly |
||
Air damper case assembly |
||
Air conditioning control assembly |
||
Temperature control: Cooling effectiveness is poor*3 |
Refrigerant volume |
- |
Refrigerant pressure |
||
Blower motor circuit |
||
Evaporator temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
Air conditioning compressor magnetic clutch circuit |
||
Air conditioner pressure sensor circuit*1 |
||
Cooler expansion valve |
||
Compressor with magnet clutch*1 |
||
Compressor with magnet clutch*2 |
||
Cooler condenser assembly |
||
Air mix damper control cable sub-assembly |
||
Air damper case assembly |
||
Air conditioning control assembly |
||
ECM*1 |
||
ECM*2 |
||
Temperature control: No cool air comes out*3 |
Refrigerant volume |
- |
Refrigerant pressure |
||
Blower motor circuit |
||
Evaporator temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
Air conditioning compressor magnetic clutch circuit |
||
Air conditioner pressure sensor circuit*1 |
||
Cooler expansion valve |
||
Compressor with magnet clutch*1 |
||
Compressor with magnet clutch*2 |
||
Cooler condenser assembly |
||
Air mix damper control cable sub-assembly |
||
Air damper case assembly |
||
Air conditioning control assembly |
||
ECM*1 |
||
ECM*2 |
||
Temperature control: No warm air comes out |
Blower motor circuit |
|
Ambient temperature sensor circuit |
||
Air mix damper control cable sub-assembly |
||
Air conditioning radiator assembly |
||
Air damper case assembly |
||
Air conditioning control assembly |
||
ECM*1 |
||
ECM*2 |
||
Temperature control: Output air is warmer or cooler than the set temperature or response is slow |
Refrigerant volume |
- |
Refrigerant pressure |
||
Blower motor circuit |
||
Evaporator temperature sensor circuit*3 |
||
Ambient temperature sensor circuit |
||
Air conditioning compressor magnetic clutch circuit |
||
Air conditioner pressure sensor circuit*1 |
||
Air filter sub-assembly*3 |
||
Cooler expansion valve*3 |
||
Compressor with magnet clutch*1 |
||
Compressor with magnet clutch*2 |
||
Air mix damper control cable sub-assembly |
||
Air inlet damper control cable sub-assembly |
||
Air conditioning radiator assembly |
||
Air damper case assembly |
||
Air conditioning control assembly |
||
ECM*1 |
||
ECM*2 |
||
Temperature control: No temperature control (only MAX COLD or MAX HOT) |
Blower motor circuit |
|
Evaporator temperature sensor circuit*3 |
||
Ambient temperature sensor circuit |
||
Air filter sub-assembly*3 |
||
Air mix damper control cable sub-assembly |
||
Air conditioning control assembly |
||
No air inlet control |
Air inlet damper control cable sub-assembly |
|
Air conditioning control assembly |
||
No air flow mode control |
Defroster damper control cable sub-assembly |
|
Air conditioning control assembly |
*1: for 1PP
*2: for 1KR-FE
*3: w/ Cooler System