8NR-FTS COOLING SERVICE DATA
Condition |
Specified Condition |
|---|---|
Standard valve opening temperature |
80 to 84°C (176 to 183°F) |
Standard valve lift |
8.0 mm (0.315 in.) or more at 95°C (203°F) |
Condition |
Specified Condition |
|---|---|
Standard valve opening temperature |
76 to 80°C (169 to 176°F) |
Standard valve lift |
8.0 mm (0.315 in.) or more at 91°C (196°F) |
Item |
Condition |
Specified Condition |
|---|---|---|
Cooling fan motor |
Battery voltage applied at 20°C (68°F) |
11.2 to 17.2 A |
No. 2 cooling fan motor |
Battery voltage applied at 20°C (68°F) |
11.2 to 17.2 A |
Item |
Condition |
Specified Condition |
|---|---|---|
Reserve tank cap |
Standard pressure (for brand-new reserve tank cap) |
93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi) |
Minimum pressure (for used reserve tank cap) |
79 kPa (0.8 kgf/cm2, 11.5 psi) |
Item |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|---|
FAN NO. 1 relay |
3 - 5 |
Battery voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
Battery voltage applied between terminals 1 and 2 |
Below 1 Ω |
Capacity |
Classification |
|---|---|
for CVT: 6.4 liters (6.8 US qts, 5.6 Imp. qts) |
TOYOTA vehicles are filled with TOYOTA SLLC at the factory. In order to avoid damaging the engine cooling system and other technical problems, only use TOYOTA SLLC or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids). |
for Manual Transaxle: 6.2 liters (6.6 US qts, 5.5 Imp. qts) |