1AD-FTV COOLING SERVICE DATA

Thermostat

Standard Valve Opening Temperature

80 to 84°C (176 to 183°F)

Standard Valve Lift

10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)

Cooling fan motor

Battery voltage applied at 20°C (68°F)

11.2 to 14.5 A

No. 2 cooling fan motor

Battery voltage applied at 20°C (68°F)

11.2 to 14.5 A

Fan No. 1 relay

3 - 5

10 kΩ or higher

(Battery voltage not applied between terminals 1 and 2)

3 - 5

Below 1Ω

(Battery voltage applied between terminals 1 and 2)

Fan No. 2 relay

3 - 4

Below 1Ω

(Battery voltage not applied between terminals 1 and 2)

3 - 5

10 kΩ or higher

(Battery voltage not applied between terminals 1 and 2)

3 - 4

10 kΩ or higher

(Battery voltage applied between terminals 1 and 2)

3 - 5

Below 1Ω

(Battery voltage applied between terminals 1 and 2)

Fan No. 3 relay

3 - 5

10 kΩ or higher

(Battery voltage not applied between terminals 1 and 2)

3 - 5

Below 1Ω

(Battery voltage applied between terminals 1 and 2)

Radiator cap sub-assembly

Standard valve (for brand-new cap)

94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)

Minimum standard valve (for used cap)

78 kPa (0.8 kgf/cm2, 11.3 psi)

Table 1. COOLANT

Capacity

Classification

w/o Combustion Type Power Heater: 7.4 liters (7.8 US qts, 6.5 Imp. qts)

w/ Combustion Type Power Heater: 7.8 liters (8.2 US qts, 6.9 Imp. qts)

Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).