STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY INSPECTION

PROCEDURE

  1. INSPECT ECO RUN CANCEL SWITCH ASSEMBLY (w/o Pre-crash Safety System)

    1. A322396C01

      *a

      Component without harness connected

      (Eco Run Cancel Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Switch Condition

      Specified Condition

      6 (ECU) - 3 (E)

      Pushed

      Below 1 Ω

      Not pushed

      10 kΩ or higher

      If the result is not as specified, replace the eco run cancel switch assembly.

  2. INSPECT ECO RUN CANCEL SWITCH ASSEMBLY (COMBINATION SWITCH ASSEMBLY) (w/ Pre-crash Safety System)

    1. A353932C01

      *a

      Component without harness connected

      (Eco Run Cancel Switch Assembly (Combination Switch Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Switch Condition

      Specified Condition

      6 (ECU) - 3 (E)

      Pushed

      Below 1 Ω

      Not pushed

      10 kΩ or higher

      If the result is not as specified, replace the eco run cancel switch assembly (combination switch assembly).