EGR BYPASS VALVE SWITCHING VALVE INSTALLATION

PROCEDURE


  1. INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY


    1. Install the No. 1 vacuum switching valve assembly to the bracket with the screw.

      Torque:
      1.4 N*m  { 14 kgf*cm, 12 in.*lbf }
    2. Connect the vacuum hose to the No. 1 vacuum switching valve assembly.

  2. INSTALL VACUUM CONTROL VALVE SET


    1. Install the vacuum control valve set to the intake manifold with the 2 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Connect the 2 vacuum hoses to the No. 2 vacuum transmitting pipe sub-assembly and No. 2 EGR valve assembly.

    3. Connect the engine wire bracket with the bolt.

      Torque:
      18.5 N*m  { 189 kgf*cm, 14 ft.*lbf }
  3. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY

    Click here