LIN COMMUNICATION SYSTEM, Diagnostic DTC:B1249
| DTC Code | DTC Name |
|---|---|
| B1249 | Double Locking ECU Communication Stop |
DESCRIPTION
The main body ECU (multiplex network body ECU) stores this DTC when communication with the double lock door control relay assembly is interrupted for 10 seconds or more.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
|---|---|---|---|
B1249 |
Double Locking ECU Communication Stop |
No communication between double lock door control relay assembly and main body ECU (multiplex network body ECU) for 10 seconds or more |
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly.
*a
Component without harness connected
(Instrument Panel Junction Block Assembly)
-
-
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
Tip:This inspection is to check the LIN communication line in the instrument panel junction block assembly that connects the wire harness to the built-in main body ECU (multiplex network body ECU).
Standard Resistance
Tester Connection
Condition
Specified Condition
3C-22 - MB-16 (LIN2)
Always
Below 1 Ω
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) - DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY)
Disconnect the E107 double lock door control relay assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3C-22 - E107-9 (MPX1)
Always
Below 1 Ω
E107-9 (MPX1) - Body ground
Always
10 kΩ or higher
3C-22 - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY - BATTERY, BODY GROUND)
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
E107-1 (+B) - E107-14 (GND)
Always
11 to 14 V
E107-7 (CPUB) - E107-14 (GND)
Always
11 to 14 V
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
E107-14 (GND) - Body ground
Always
Below 1 Ω
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY
Replace the double lock door control relay assembly.
Result
Proceed to
NEXT
CHECK DTC OUTPUT
Clear the DTCs.
Body Electrical > Main Body > Clear DTCs
Recheck for DTCs.
Body Electrical > Main Body > Trouble Codes
OK
DTC B1249 is not output.
Result
Proceed to
OK
NG
OK END (DOUBLE LOCK DOOR CONTROL RELAY ASSEMBLY WAS DEFECTIVE)