PURGE VALVE INSPECTION
PROCEDURE
INSPECT PURGE VALVE (PURGE VSV)
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
23 to 26 Ω
If the result is not as specified, replace the purge valve (purge VSV).
-
*a
Port E
*b
Port F
*c
Air
Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).
OK
Measurement Condition
Specified Condition
Battery voltage applied between terminals 1 and 2
Air flows from port (F)
Battery voltage not applied between terminals 1 and 2
Air does not flow
If the result is not as specified, replace the purge valve (purge VSV).
-