METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

A005CEDE51
*a from Auxiliary Battery
*b from IG2 Relay
*c Combination Meter Sub-assembly (Meter Circuit Plate)

CAUTION / NOTICE / HINT

Note

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER SUB-ASSEMBLY CIRCUIT)


    1. A005D2RE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Meter Sub-assembly)

      Disconnect the L27 combination meter sub-assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L27-11 (ES) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L27-2 (IG+) - Body ground Power switch off Below 1 V
      Power switch on (IG) 11 to 14 V
      L27-1 (B) - Body ground Power switch off 11 to 14 V

    OK
    NG