PATTERN SELECT SWITCH INSPECTION
PROCEDURE
INSPECT PATTERN SELECT SWITCH ASSEMBLY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
1 (MSW2) - 4 (MSW1)
Combination switch (SPORT) on
Below 1 Ω
Combination switch (SPORT) off
10 kΩ or higher
Table 1. Text in Illustration *a
Component without harness connected
(Pattern Select Switch Assembly)
If the result is not as specified, replace the pattern select switch assembly.
-