PATTERN SELECT SWITCH INSPECTION

PROCEDURE

  1. INSPECT NO. 1 PATTERN SELECT SWITCH ASSEMBLY

    1. C239992C01

      *a

      Component without harness connected

      (No. 1 Pattern Select Switch Assembly)

      Measure the resistance according to the value in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      11 (MSW1) - 8 (MSW2)

      Pressed

      Below 1 Ω

      Not pressed

      10 kΩ or higher

      If the result is not as specified, replace the No. 1 pattern select switch assembly.