PROCEDURE
INSPECT THERMOSTAT
Immerse the thermostat in water and then gradually heat the water.
Tech Tips
Hold the thermostat with a wire or the like, so that the thermostat does not come into contact with the bottom of the container.
Check the valve opening temperature of the thermostat.
| Valve opening temperature |
|---|
| 48 to 52°C (118 to 126°F) |
Tech Tips
If the valve opening temperature is not as specified, replace the thermostat.
| *a | Valve Lift |
Check the valve lift.
| Valve lift |
|---|
| 6.0 mm (0.236 in.) or more at 63°C (145°F) |
Tech Tips
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the water inlet with thermostat is at low temperatures (below 45°C (113°F)).
Tech Tips
If it is not fully closed, replace the thermostat.