GENERATOR INSPECTION
PROCEDURE
INSPECT BRUSH
-
Using a vernier caliper, measure the length of the exposed brushes.
Standard exposed length
11.2mm (0.441 in.)
Minimum exposed length
2.0 mm (0.0787 in.)
Table 1. Text in Illustration *a
Exposed Length
If the exposed length is less than the minimum, replace the generator regulator assembly.
-